The Schneider Electric Back-UPS offers power and surge protection for wireless networks, computers,gaming consoles and other electronics in your business. This UPS supply battery backup duringoutages and unstable voltage fluctuations, as well as provide protection from damaging surges and
spikes. It’s equipped with data line surge
protection which safeguards your equipment and valuablefiles from “back door” surges traveling along data line. They are the choice helps to protect yoursensitive electronics.
Run time for load WMin-max: 33-330 W | 2min 33s |
---|---|
Main Input Voltage | 120 V |
Main Output Voltage | 120 V |
Rated power in W | 330 W |
Rated power in VA | 550 VA |
Input Connection Type | NEMA 5-15P |
output connection type | 4 NEMA 5-15R 2 NEMA 5-15R surge |
Cable length | 6 ft (1.83 m) |
Battery type | Lead-acid battery |
Provided equipment | User manual USB cable |
Number of power module free slots | 0 |
---|---|
Number of power module filled slots | 0 |
Redundant | No |
Colour | Black |
---|---|
Height | 6.50 in (16.5 cm) |
Width | 3.58 in (9.1 cm) |
Depth | 11.18 in (28.4 cm) |
Net weight | 13.89 lb(US) (6.3 kg) |
Mounting location | Front |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
Two post mountable | 0 |
USB compatible | Yes |
Network frequency | 50/60 Hz +/- 3 Hz auto-sensing |
---|---|
Input voltage limits | 98...140 V |
Maximum configurable power in W | 330 W |
---|---|
Output frequency | 50/60 Hz +/- 3 Hz sync to mains |
UPS type | Standby |
Wave type | Stepped approximation to a sinewave |
Maximum output current | 10 A |
Maximum configurable power in VA | 550 VA |
Transfer time | 8 ms typical : 10 ms maximum |
Product certifications | CUL listed California Energy Commission (CEC) ENERGY STAR V2.0 (USA) |
---|---|
Equipment protection policy | Lifetime : $100000 |
ambient air temperature for operation | 32…104 °F (0…40 °C) |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...10000 ft |
Ambient air temperature for storage | 5…113 °F (-15…45 °C) |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0…50000 ft (0.00…15240.00 m) |
Acoustic level | 45 dBA |
heat dissipation | 24 Btu/h |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Battery recharge time | 8 h |
Number of battery replacement quantity | 1 |
Battery charger power | 10 W rated |
Battery power in VAH | 106 VAh capacity 78 VAh runtime |
Battery life | 4…6 year(s) |
Replacement battery | RBC2 |
Battery graph comments | This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v |
Control panel | LED status display with on line : on battery : replace battery and overload indicators |
---|---|
Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Control panel | LED status display with on line : on battery : replace battery and overload indicators |
Surge energy rate | 468 J |
---|---|
Noise suppression | Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 10.24 in (260 mm) |
Package 1 Width | 16.14 in (410 mm) |
Package 1 Length | 7.48 in (190 mm) |
Package 1 Weight | 10.58 lb(US) (4.8 kg) |
SCC14 | 10731304421037 |
Warranty | 3 years repair or replace |
---|