The APC Back-UPS offers power and surge protection for wireless networks, computers,gaming consoles and other electronics in your business. This UPS supply battery backup duringoutages and unstable voltage fluctuations, as well as provide protection from damaging surges and
spikes. It’s equipped with data line surge
protection which safeguards your equipment and valuablefiles from “back door” surges traveling along data line. They are the choice helps to protect yoursensitive electronics.
Lead time | Usually in Stock |
---|
Run time for load Min-max: 30-300 W 3min 24sMain Input Voltage 120 V Main Output Voltage 120 V Rated power in W 300 W Rated power in VA 500 VA Input Connection Type NEMA 5-15P output connection type 3 NEMA 5-15R
3 NEMA 5-15R surgeCable length 6 ft (1.83 m) Number of cables 1 Battery type Lead-acid battery Provided equipment CD with software
Cord management straps
User manual
USB cableNumber of power module free slots 0 Number of power module filled slots 0 Redundant No Colour Beige Height 6.50 in (16.5 cm) Width 3.58 in (9.1 cm) Depth 11.18 in (28.4 cm) Net weight 13.82 lb(US) (6.27 kg) Mounting location Front Mounting preference No preference Mounting mode Not rack-mountable Two post mountable 0 USB compatible Yes Network frequency 50/60 Hz +/- 3 Hz auto-sensing Input voltage limits 98...140 V Maximum configurable power in W 300 W Output frequency 50/60 Hz +/- 3 Hz sync to mains UPS type Standby Wave type Stepped approximation to a sinewave Maximum output current 10 A Maximum configurable power in VA 500 VA Transfer time 8 ms typical : 12 ms maximum Product certifications CUL listed
California Energy Commission (CEC)
ENERGY STAR V2.0 (USA)
Industry CanadaEquipment protection policy Lifetime : $100000 ambient air temperature for operation 32…104 °F (0…40 °C) Relative humidity 0…95 % Operating altitude 0...10000 ft Ambient air temperature for storage 5…113 °F (-15…45 °C) Storage Relative Humidity 0…95 % Storage altitude 0…50000 ft (0.00…15240.00 m) Acoustic level 45 dBA heat dissipation 24 Btu/h Run Time View Runtime Graph Efficiency View Efficiency Graph Number of battery filled slots 0 Number of battery free slots 0 Battery recharge time 8 h Number of battery replacement quantity 1 Battery voltage 12 V Battery capacity 7.0 Ah Battery charger power 10 W rated Battery power in VAH 106 VAh capacity
78 VAh runtimeBattery life 4…6 year(s) Replacement battery RBC2 Battery graph comments This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v Extended runtime 0 Control panel LED status display with on line : on battery : replace battery and overload indicators Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm Control panel LED status display with on line : on battery : replace battery and overload indicators Surge energy rate 480 J Noise suppression Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 Let through voltage rating 300 V Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 10.35 in (26.3 cm) Package 1 Width 14.06 in (35.7 cm) Package 1 Length 6.89 in (17.5 cm) Package 1 Weight 15.32 lb(US) (6.95 kg) SCC14 10731304016301 Warranty 3 years repair or replace